Enhanced Mosaic M1S safety controller

New Enhanced Mosaic M1S safety controller enables to build and control even wider safety system. Main modules can be used as stand-alone device or with expansion units. Simple drag & drop programming can be used to create complex logical conditions using logical operators and safety functions via an easy, intuitive graphic configuration interface. Mosaic is able to reach PL e – Cat. 4 according to ISO 13849-1.

Minimum number of modules M1 used as stand-alone

1 module

  • 8 inputs
  • + 2 EDM/RST
  • + 2 safety outputs
  • + 2 status outputs

Max number of modules M1 + 14 expansions

15 modules

  • 128 inputs
  • + 16 EDM/RST
  • + 16 safety outputs
  • + 32 status outputs
  • The system can have not more than 4 expansions of the same type

Minimum number of modules M1S used as stand-alone

1 module

  • 8 inputs
  • + 4 EDM/RST
  • + 4 safety outputs
  • + 4 status outputs

Max number of modules M1S + 14 expansions

15 modules

  • 128 inputs
  • + 32 EDM/RST
  • + 32 safety outputs
  • + 48 status outputs
  • The system can have not more than 4 expansions of the same type