Search
Close this search box.

Enhanced Mosaic M1S safety controller

New Enhanced Mosaic M1S safety controller enables to build and control even wider safety system. Main modules can be used as stand-alone device or with expansion units. Simple drag & drop programming can be used to create complex logical conditions using logical operators and safety functions via an easy, intuitive graphic configuration interface. Mosaic is able to reach PL e – Cat. 4 according to ISO 13849-1.

Minimum number of modules M1 used as stand-alone

1 module

  • 8 inputs
  • + 2 EDM/RST
  • + 2 safety outputs
  • + 2 status outputs

Max number of modules M1 + 14 expansions

15 modules

  • 128 inputs
  • + 16 EDM/RST
  • + 16 safety outputs
  • + 32 status outputs
  • The system can have not more than 4 expansions of the same type

Minimum number of modules M1S used as stand-alone

1 module

  • 8 inputs
  • + 4 EDM/RST
  • + 4 safety outputs
  • + 4 status outputs

Max number of modules M1S + 14 expansions

15 modules

  • 128 inputs
  • + 32 EDM/RST
  • + 32 safety outputs
  • + 48 status outputs
  • The system can have not more than 4 expansions of the same type

For more information
Juuso Lehto

juuso.lehto@sahkolehto.mm-dev.fi